Filter
Mobile Conditioning System for temporary CEMS, Thermoelectric Cooler Flow Rate up to 250 l/h, integrated Gas Sample Pump and Temoerature controller for PSG Plus Flex Plane integrated in a robust Peli Case
Controlled Sample Line for up to 200°C holding temperature, cut-to-length for CEMS, max. length 300m (heating circuit 73 m) and up to PTFE /PFA inner tubes (exchangable as option)
Controlled Sample Line up to 150°C holding temperature, cut-to-length with PTFE / PFA or stainless steel tubes, heating cable certified for ATEX Zone 1: II 2G Ex IIC und IEcEX
Controlled Sample Line up to 180°C holding temperature, cut-to-length with PTFE / PFA or stainless steel tubes, heating cable certified for ATEX Zone 1: II 2G Ex IIC und IEcEX
Regulated line for up to 200°C holding temperature, with 2 heated ends, can be shortened, max. 300 m (heating circuit length 73m), 2 x PTFE inner core.
Controlled Sample Line for up to 200°C holding temperature, cut-to-length with PTFE /PFA tubes, max. length 300m (heating circuit 73 m) and small bending radius
Controlled All-in-One Sample Line with 200°C holding temperature and configurations for the complete operation of the probe and preheated back purge air
Controlled Sample Line up to 200°C holding temperature, pre-fabricated (no cut-to-length) with PTFE / PFA tubes, coextruded with extreme robust Ringwell Jacket
Controlled Sample Line up to 200°C holding temperature, pre-fabricated (no cut-to-length) wiith PTFE / PFA tubes, coextruded jacket extreme flexible
Controlled Probe up to 315°C holding temperature for Process and Emission measurement with high dust load
Self limiting Probe with 90 °C holding temperature with explosion proof for ATEX Zone 1 II 2G Ex d IIC T3 Gb
Controlled DeNOx Probe up to 315°C holding temperature for SCR and SNCR applications with separator vessel for Ammonia salts
Controlled Probe up to 200°C holding temperature and double back purge for Process measurement with high dust load
Self limiting mobile Probe heated up to 180°C holding temperature for temporary CEMS
High Performance Compressor Cooler (outlet dew point optimized) with 1-2 Gas Path, Heat Exchanger in various Materials and flow rates up to 250 l/h
High Performance Compressor Cooler (outlet dew point optimized) with 1-2 Gas Path, Heat Exchanger in various Materials and flow rates up to 350 l/h
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-2 Gas Path, Heat Exchanger in various Materials, flow rates up to 350 l/h for Atex-zone 2 (II 3G Ex nA nC T4 Gc)
High Performance Compressor Cooler (outlet dew point optimized) with 1-4 Gas Path, Heat Exchanger in various Materials and flow rates up to 500 l/h
High Performance Compressor Cooler (outlet dew point optimized) with 1-4 Gas Path, Heat Exchanger in various Materials and flow rates up to 500 l/h
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-4 Gas Path, Heat Exchanger in various Materials, flow rates up to 500 l/h for ATEX EX II 2G Ex px de [ai] IIC T4 Gb