Properties
- Applicable in Ex-zone 1 and 2
Unadulterated pumping of sample gas
Especially corrosion resistant sample gas wetted components made of PTFE, PVDF and FFPM
Pump capacity 7,5l/min without pressure
Tension optimized long-lasting PTFE-diaphragm
Long lifetime
Maintenance free operation
IP66 housing
Simple mounting and integration
Operation in any position
Technical Data + Options
Application
The diaphragm sample gas pump PSP87 ATEX is used for continuous extractive gas analytics in explosion zones. It mainly serves for unadulterated sucking and pumping of highly aggressive and corrosive sample gas from sample point to the analyzer house resp. analyzer. Typical applications are emission measurements e.g. in waste incinerations and process measurements e.g. in chemical, petro-chemical, steel-, glass- or cement-industry.
Technology
The PSP87 ATEXis a reliable diaphragm pump with compact dimensions that guarantees an optimum integration in systems and devices. It has a highly gas tight PVDF-pump head whose components have been developed especially for pumping of aggressive and corrosive gases. Special valves made of FFPM ensure a high tolerance to vapor and condensate. The patented PTFE-coated diaphragm was optimized using the finite-element-method. The results are an extremely long lifetime of the diaphragm and a high pneumatic performance of the pump. The pump is operating absolutely oil-free and ensures therefore an unadulterated pumping, evacuating and compressing of gases. The pump is ready for mounting and can operate in any position.
Functions
Core of the PSP87 ATEX is the elastic diaphragm which is moved up and down in its center by an eccentric. In this way gas is pumped through self-opening and-closing valves. Due to the IP66 housing the pump is protected perfectly against spray water, dust and dirt.
You may also be interested in
Liquid Stop filter as protection of the analyser against intrusion of liquid particles.
Liquid Stop filter as protection of the analyser against intrusion of liquid and solid particles, stainless steel variant.
Solid particle filters for reliable protection of the analyser against solid particles
Self limiting Probe with 180°C holding temperature for use in IP 65 housing and explosion proof for ATEX Zone 1 II 2G Ex d IIC T3 and IEcEX
Self limiting Probe with 180°C holding temperature for use in IP 65 housing and explosion proof for ATEX Zone 1 II 2G Ex d IIC T3 or IECEx
Self regulating Sample Line up to 120°C holding temperature, cut-to-length with PTFE / PFA or stainless steel tubes, fully certified for ATEX Zone 1: II 2G Ex IIC
Self regulating Sample Line up to 120°C holding temperature, cut-to-length with PTFE / PFA or stainless steel tubes, fully certified for ATEX Zone 1: II 2G Ex IIB
Controlled Sample Line up to 180°C holding temperature, cut-to-length with PTFE / PFA or stainless steel tubes, heating cable certified for ATEX Zone 1: II 2G Ex IIC und IEcEX
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-4 Gas Path, Heat Exchanger in various Materials, flow rates up to 500 l/h for ATEX EX II 2G Ex px de [ai] IIC T4 Gb
High Performance Compressor Cooler (outlet dew point optimized) with 1-4 Gas Path, Heat Exchanger in various Materials and flow rates up to 500 l/h
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-2 Gas Path, Heat Exchanger in various Materials, flow rates up to 350 l/h for Atex-zone 2 (II 3G Ex nA nC T4 Gc)
Self limiting Probe with 90 °C holding temperature with explosion proof for ATEX Zone 1 II 2G Ex d IIC T3 Gb
Controlled Sample Line up to 180°C holding temperature, cut-to-length with PTFE / PFA or stainless steel tubes, heating cable certified for ATEX Zone 1: II 2G Ex IIC und IEcEX
Controlled Sample Line up to 150°C holding temperature, cut-to-length with PTFE / PFA or stainless steel tubes, heating cable certified for ATEX Zone 1: II 2G Ex IIC und IEcEX
NO2/NO Converter as 19″ rack version with and without bypass valve or in stainless steel housing for wall mounting without bypass valve
Liquid Stop filter as protection of the analyser against intrusion of liquid particles down to 0,2µm
Corrosion resistant heated PTFE diaphragm sample gas pump , 10,5 l/min flow rate, Motor IP54, Heater IP20 for ATEX Ex II 2G Ex h IIB+H2 T4 Gb
Corrosion resistant PTFE diaphragm sample gas pump for low maintenance operation 7,5 l/min. flow rate, IP54
Corrosion resistant PTFE diaphragm sample gas pump for low maintenance operation and compact design 5.5 l/min. flow rate, IP20
Corrosion resistant PTFE diaphragm sample gas pump (Integration into the MAK product line possible)
PID Temperature Controller for PSG Gas Sampling Probes and Heated Lines (tabletop device)
PID Temperature Controller for PSG Gas Sampling Probes and Heated Lines (tabletop device)
Condensate sensor for detecting condensate breakthrough in the analyzer system to protect the analyzer
Aerosol Filter for protection of the analyser against aerosols by durable corrosion resistant materials
Adsorption Filter filled with various adsorption materials by large reaction surface